Water Treatment | Phenol Destruct

We can match any competitors Phenol Destructs systems and products at a lower cost.

The Chemistry of Phenol Destruct

ClarityChem expertise encompasses all current Phenol destruct technologies including; carbon absorption, advanced oxidation chemistries such as Fenton's, peroxide, super chlorination, chlorine dioxide, ozone, specialized oxidants, and our own CC-9060.

We can evaluate all these technologies and provide our recommendation based on jar testing results from your waste stream.

Phenol Destruct Technologies: Overview

Carbon tanks remove phenol through absorption, but eventually become exhausted. Depending on size and loading they cost about $2500 per regeneration, and require "activation" prior to use. They can become plugged from influent solids, and require a consistent flow rate (removal based on contact time), for optimal results. They are not reliable for varying untreated phenol levels and or flow variation.

Ozone - not very effective with waste streams that are high in organics. Also not effective for ring structures organics like phenols.

Hydrogen peroxide - needs a catalyst for reaction.

Fenton's requires an acidic pH, ferrous iron, hydrogen peroxide, pH adjustment for removal.

ClarityChem experts will evaluate your process waste and determine the optimal program for phenol and other contaminant removal. Based on waste treatment testing we will supply a program recommendation for your facility.

Environmentally friendly.....Competitively priced
Contact us today for free consultation and a customized solution.

Contact Us Today

Have a question or need a custom quote?

We offer custom integrated solutions for your most challenging water and process needs.
Contact us today at 888-229-2099